Console Output and Serial Terminals: Difference between revisions

From MediaWiki
Jump to navigationJump to search
Line 87: Line 87:
</div>
</div>
* Edit custom file: "/etc/systemd/system/serial-getty57600@.service" and set the fixed baud rate of 57600 on the "'''ExecStart'''" line.
* Edit custom file: "/etc/systemd/system/serial-getty57600@.service" and set the fixed baud rate of 57600 on the "'''ExecStart'''" line.
<pre class="programListing">
#  This file is part of systemd.
#
#  systemd is free software; you can redistribute it and/or modify it
#  under the terms of the GNU General Public License as published by
#  the Free Software Foundation; either version 2 of the License, or
#  (at your option) any later version.
[Unit]
Description=Serial Getty on %I
BindTo=dev-%i.device
After=dev-%i.device systemd-user-sessions.service plymouth-quit-wait.service
After=rc-local.service
# If additional gettys are spawned during boot then we should make
# sure that this is synchronized before getty.target, even though
# getty.target didn't actually pull it in.
Before=getty.target
[Service]
Environment=TERM=vt100
ExecStart=-/sbin/agetty %I 57600
Restart=always
RestartSec=0
UtmpIdentifier=%I
KillMode=process
# Some login implementations ignore SIGTERM, so we send SIGHUP
# instead, to ensure that login terminates cleanly.
KillSignal=SIGHUP
</pre>

Revision as of 15:52, 22 May 2011

Overview

This page describes different methods for setting up a serial console post booting up an NST system. See Getting Started - Server Boot for setting up a serial console initially during a NST Live boot.


Serial Console On NST 2.13.0

Add Serial Console On Device: /dev/ttyS0

Use the following command to manually enable the serial console on NST versions 2.13.0 using upstart. This example will set the serial baud rate to: "57600" and use serial device: "/dev/ttyS0".

[root@probe ~]# initctl emit --no-wait fedora.serial-console-available ttyS0 57600
[root@probe ~]# 

A user login prompt should now be active on serial device: "/dev/ttyS0".


Serial Console On NST 2.15.0 or Above

Add A Serial Console On Device: /dev/ttyS0

See the topic: "Enabling systemctl Bash Completion" for making it quick and easy to complete the systemctl command.

Use the following command to manually enable the serial console on NST versions 2.15.x or above using systemd. This example will use the current baud rate (agetty -s option) set typically during a boot time and use serial device: "/dev/ttyS0". If one needs to adjust the baud rate, send a break character on your communications application to cycle through the baud rate list (i.e., In this example: 115200, 38400 and 9600).

[root@probe ~]# systemctl start serial-getty@ttyS0.service
[root@probe ~]# 

A user login prompt should now be active on serial device: "/dev/ttyS0". To get the serial console status use the systemctl command as follows:

[root@probe ~]# systemctl status serial-getty@ttyS0.service
serial-getty@ttyS0.service - Serial Getty on ttyS0
          Loaded: loaded (/lib/systemd/system/serial-getty@.service)
          Active: active (running) since Tue, 17 May 2011 16:59:56 -0400; 5min ago
        Main PID: 31524 (agetty)
          CGroup: name=systemd:/system/serial-getty@.service/ttyS0
                  └ 31524 /sbin/agetty -s ttyS0 115200 38400 9600
[root@probe ~]# 

Add An Additional Serial Login Device: /dev/ttyUSB0

One can add an additional Serial user login session on a serial device. If your NST system does not have a physical serial port, you can plugin a USB To Serial Converter device for user login. In this example we are adding a USB To Serial Converter which attaches as device: "ttyUSB0". Simply start a serial login on this device as follows:

[root@probe ~]# systemctl start serial-getty@ttyUSB0.service
[root@probe ~]# 

A user login prompt should now be active on serial device: "/dev/ttyUSB0". To get the serial console status for this device use the systemctl command as follows:

[root@probe ~]# systemctl status serial-getty@ttyUSB0.service
serial-getty@ttyUSB0.service - Serial Getty on ttyUSB0
	  Loaded: loaded (/lib/systemd/system/serial-getty@.service)
	  Active: active (running) since Fri, 20 May 2011 21:13:55 -0400; 3min 24s ago
	Main PID: 1273 (agetty)
	  CGroup: name=systemd:/system/serial-getty@.service/ttyUSB0
		  └ 1273 /sbin/agetty -s ttyUSB0 115200 38400 9600
[root@probe ~]#

To make this configuration permanent add the following:

[root@probe ~]# ln -sf /lib/systemd/system/getty@.service /etc/systemd/system/getty.target.wants/getty@ttyUSB0.service
[root@probe ~]# systemctl daemon-reload
[root@probe ~]# systemctl start getty@ttyUSB0.service
[root@probe ~]#


Steps To Add A Custom Serial Login Device: "/dev/ttyS1"

Use the following procedure to add a custom serial login device under systemd control. In this example we will add the ability for user login on the second serial device: "/dev/ttyS1" using a fixed baud rate of 57600 and 8-bits clean with no flow control.

  • Get a copy of "/lib/systemd/system/serial-getty@.service" and place it in directory: "/etc/systemd/system" and give it a custom name (e.g., "serial-getty57600@.service").
[root@probe ~]# cp /lib/systemd/system/serial-getty\@.service /etc/systemd/system/serial-getty57600\@.service
[root@probe ~]# 
  • Edit custom file: "/etc/systemd/system/serial-getty57600@.service" and set the fixed baud rate of 57600 on the "ExecStart" line.
#  This file is part of systemd.
#
#  systemd is free software; you can redistribute it and/or modify it
#  under the terms of the GNU General Public License as published by
#  the Free Software Foundation; either version 2 of the License, or
#  (at your option) any later version.

[Unit]
Description=Serial Getty on %I
BindTo=dev-%i.device
After=dev-%i.device systemd-user-sessions.service plymouth-quit-wait.service
After=rc-local.service

# If additional gettys are spawned during boot then we should make
# sure that this is synchronized before getty.target, even though
# getty.target didn't actually pull it in.
Before=getty.target

[Service]
Environment=TERM=vt100
ExecStart=-/sbin/agetty %I 57600
Restart=always
RestartSec=0
UtmpIdentifier=%I
KillMode=process

# Some login implementations ignore SIGTERM, so we send SIGHUP
# instead, to ensure that login terminates cleanly.
KillSignal=SIGHUP